> PLCs >Schneider Electric Industries MODBUS SLAVE Driver
Note: ā Precautions for adding a new driver onto Windows Vista/7
Installation (This file is self-extracting.)
Update History: [Ver. 1.13.05] (Jul. 27, 2010) The following issues were corrected:
[Ver. 1.13.04] (Feb. 18, 2010) The following issue was corrected:
[Ver. 1.13.03] The following setting was added:
[Ver. 1.12.02] (Feb. 12, 2008) The following settings were added:
[Ver. 1.11.02] (Oct. 1, 2007) The following setting was added:
[Ver. 1.10.02] (Feb. 5, 2007) The following issues were corrected:
Last Updated : Jul 27, 2010
|
GSM Modem configuration guide ā June 2008 4 Hardware Guide continued. GSM MODEM: SR2COM02 The new Schneider Electric modem SR2COM02 is a new quad band modem which will work in North America as well as Europe. Thus enabling us to give a complete solution for remote monitoring of Zelio Logic including the modem. PLC Comli driver halts on modem connection. Iām using the General Comli 31 protocol driver, which has the short name 7TCML with ID 13.
Product code: SH-DR-N4-TAC
The TAC driver enables direct communication between Schneider Electric TAC Xenta controllers and Tridium Niagara powered devices. Xenta series include a range of freely programmable controllers, which support a proprietary TAC protocol on top of open LonTalk medium.
All components of the driver, the device and the points are perfectly integrated into the framework: this allows for better efficiency in the design and maintenance of the systems, which results in lower costs.
Schneider Electric Modems Driver Download 64-bit
A Niagara device with a Xenta driver provides a unique and cost-effective solution for Schneider building management system retrofit, seamless integration of various protocols and convenient makeover of front-end software. Xenta devices should not be reprogrammed and original TAC Vista front-end can co-exist with Niagara on the same network until the end of the commissioning.
Niagara uses a standard LON card to connect to Xenta network. Xenta device points and schedules are imported into Niagara automatically without complex engineering. They retain their names, descriptions and unit facets, which greatly simplifies integration process.
Features
- Works with all TAC Xenta devices
- Uses standard LON option card
- Provides automatic device discovery
- Allows automatic point discovery or point import from program file
- Enables point read and write
- Physical inputs and outputs could be overridden, i.e. for maintenance
- Supports Xenta time schedules
- Enables read-only, write-only and read-write access to schedules
- Flexible point polling intervals
- Displays point names, descriptions and unit facets
- Ideal for retrofit application
- TAC Vista front-end could coexist with Niagara until the end of the commissioning
Supported systems
- Niagara AX
- Niagara N4
Supported devices
Schneider Electric Modems Driver Download Windows 7
- Xenta 281
- Xenta 282
- Xenta 283
- Xenta 401
- Xenta 401:B
- Xenta 401:C
- Xenta 301
- Xenta 302
Requirements
- Standard LON card and LON driver
Order references
- SH-DR-N4-TAC-J3 Schneider TAC Xenta for Jace 3
- SH-DR-N4-TAC-J6 Schneider TAC Xenta for Jace 6
- SH-DR-N4-TAC-J8-250 Schneider TAC Xenta for Jace 8000 / 250 points
- SH-DR-N4-TAC-J8-1000 Schneider TAC Xenta for Jace 8000 / 1000 points
- SH-DR-N4-TAC-J8-UNL Schneider TAC Xenta for Jace 8000 / unlimited
- SH-DR-N4-TAC-SUP Schneider TAC Xenta for Supervisor
- SH-DR-N4-TAC-SUP-500 Schneider TAC Xenta for Supervisor extra 500 points